(818) 882-5000 [email protected] Northridge, CA 91324
AS9100D ISO 9001:2015

Heat Treating & Furnaces —AMS 2750 Qualified Sensors

Heat treating furnaces demand temperature sensors capable of extended high-temperature service in oxidizing, reducing, and vacuum atmospheres. Thermometrics manufactures thermocouple assemblies to AMS 2750 pyrometry requirements and CQI-9 heat treat system assessment criteria.

AMS 2750 PyrometryCQI-9 CompliantType R/S Noble MetalType K/N Base MetalMgO Protection TubesSurvey Thermocouples

Furnace Sensors Per
AMS 2750 Requirements

Sensor TypeTC TypeAMS 2750 UseMax TemperatureNotes
Control ThermocoupleType K or NProcess control, Class 2–51100°C (K) / 1250°C (N)Calibration every 90 days or per lot
Load ThermocoupleType K, N, or RPart temperature verification1480°C (R)Single-use or limited-use per AMS 2750
Survey ThermocoupleType K, N, or RTemperature uniformity survey (TUS)1480°C (R)9-point or 9+ point survey per equipment class
Monitoring ThermocoupleType K or NContinuous over-temperature alarm1250°CIndependent from control sensor
Expendable (Single-Use)Type K or NLimited-life load thermocouples1100°CNo calibration required — lot-certified wire

AMS 2750 Calibration Intervals

AMS 2750 defines recalibration intervals based on thermocouple type and usage. Base-metal (Type K/N) thermocouples used above 760°C require recalibration after no more than 90 days or 500 hours of use at temperature. Noble-metal (Type R/S) thermocouples are recalibrated annually or per lot. Thermometrics issues NIST-traceable calibration certificates with individual Seebeck coefficient correction tables for all calibrated furnace thermocouples.

01

MgO Protection Tubes

High-purity MgO tubes protect Type R and S noble-metal thermocouples from contamination in furnace atmospheres. Available in single-bore and twin-bore configurations, closed-one-end, in lengths to 60".

02

Bayonet & Ceramic-Lug Style

Bayonet-mount and ceramic-lug thermocouple assemblies for fast insertion and removal during temperature uniformity surveys. Type K and Type N, with standard calibration certificate and lot-traceable extension wire.

03

Vacuum Furnace Service

Thermocouples and RTDs for vacuum furnace applications: clean metal sheaths (no coatings or lubricants), ultra-high-purity MgO insulation, and helium leak-tested tip closures to prevent outgassing in vacuum systems below 10⁻⁴ Torr.

Ready to Specify Your Sensor?

Talk directly to the engineering team that builds your assemblies. No bots, no call centers.