(818) 882-5000 [email protected] Northridge, CA 91324
AS9100D ISO 9001:2015

Tube-Skin Weld-Pad Thermocouples —TC-60 Series

Thermometrics TC-60 series tube-skin thermocouples are precision-engineered for continuous measurement of tube-wall temperatures in reformers, fired heaters, heat exchangers, and petrochemical furnaces. Welded directly to the tube OD, the sensor monitors metal temperature rather than process fluid temperature — the critical parameter for tube life management.

TC-60-1 Bare PadTC-60-2 with HeadTC-60-3 with Compression FittingInconel 600 Pad & CableDual-Element AvailablePetro-Chemical / Power
TC-60 Series Models

Tube-Skin Configuration Guide

ModelDescriptionLead/CableHead / FittingApplication
TC-60-1Tube-Skin Weld-Pad — Bare MIMS CableMIMS extension, bare cold endNone — bare cable exitDirect wiring to junction box; retrofit applications
TC-60-2Tube-Skin Weld-Pad with Head & Compression FittingMIMS to compression fittingAluminum connection head, 1/2" NPTDCS field wiring with local junction box
TC-60-3Tube-Skin Weld-Pad — Extended MIMS TailExtended MIMS, customer-specified lengthCustom termination at cold endLong routing from furnace tube to remote panel
Specifications

TC-60 Technical Data

ParameterSpecification
TC TypeType K (standard) · Type N (high-stability option)
ToleranceASTM E230 Standard · Special Limits available
Pad MaterialInconel 600 (standard) · 316SS for lower-temp service
Pad DimensionsApprox 25mm × 20mm × 2mm; custom to drawing
MIMS Cable OD1/16" (1.6mm) standard; 1/8" (3.2mm) heavy-duty
Sheath MaterialInconel 600 (standard) · 316SS
Junction StyleGrounded (welded to pad underside)
Max Tube Temperature1100°C continuous (Inconel 600 pad)
Element ConfigSimplex (single) · Duplex (measuring + spare)
Weld MethodTIG — AWS D17.1 qualified procedure
CalibrationNIST-traceable EMF verification; cert on request

Why Tube-Skin Temperature Matters

In fired heaters and reformer furnaces, tube metal temperature is the primary indicator of tube life. Exceeding the metallurgical limit of the tube alloy — even briefly — causes permanent creep damage. Tube-skin thermocouples provide the direct metal temperature measurement that fluid-immersion sensors cannot, enabling operators to manage heat flux and extend tube service life.

Dual-Element Option

  • Channel 1Active measurement
  • Channel 2Redundant / spare
  • SwitchingManual or automatic
  • Single pad, two MIMS cablesOne weld point

Installation Note

Thermometrics can supply TC-60 assemblies with weld-pad pre-tack-welded for customer final-weld, or with pre-welded installation completed in our facility on customer-supplied tube coupons. AWS D17.1 weld procedure qualification documentation available on request.

Ready to Specify Your Sensor?

Talk directly to the engineering team that builds your assemblies. No bots, no call centers.