(818) 882-5000 [email protected] Northridge, CA 91324
AS9100D ISO 9001:2015

Resistance Temperature
Detectors —Pt100 & Pt1000

Thermometrics manufactures RTD assemblies across the full IEC 60751 accuracy spectrum. Wire-wound and thin-film sensing elements, 2-/3-/4-wire configurations, and custom sheath materials for process, laboratory, and aerospace applications.

Pt100 / Pt1000IEC 60751−200 to 850°CClass A / B / 1/3 DIN2, 3, 4-WireCustom Sheaths

RTD Performance
Parameters

ParameterSpecification
Element TypeWire-wound (ceramic / glass) · Thin-film chip
Nominal ResistancePt100 (100 Ω at 0°C) · Pt1000 (1000 Ω at 0°C)
Temperature Coefficientα = 0.00385 Ω/Ω/°C (IEC 60751 / DIN 43760)
Accuracy ClassesClass AA (±0.1°C @ 0°C) · Class A (±0.15°C) · Class B (±0.3°C) · 1/3 DIN (±0.1°C)
Operating Range−200°C to 850°C (element-dependent)
Wire Configurations2-wire · 3-wire · 4-wire (Kelvin)
Sheath OD1/16" to 1" (custom on request)
Sheath Materials316 SS · 304 SS · Inconel 600 · Inconel 625 · Titanium · Hastelloy C276
InsulationMgO · Ceramic · PTFE · Fiberglass
Process ConnectionsNPT threaded · Tri-clamp · Flanged · Compression fitting
Self-Heating Error<0.1°C typical at 1 mA excitation
Response Time (t63)0.5–8 sec (sheath-diameter-dependent)
Calibration StandardNIST-traceable · IEC 60751

Accuracy Class Summary

  • Class AA (1/3 DIN)±(0.1 + 0.0017|t|) °C
  • Class A±(0.15 + 0.002|t|) °C
  • Class B±(0.3 + 0.005|t|) °C
  • Class C (2× Class B)±(0.6 + 0.01|t|) °C

4-Wire RTD for Highest Accuracy

4-wire (Kelvin) configurations eliminate lead resistance error entirely, making them the preferred choice for laboratory and metrology applications where measurement uncertainty must be minimized. Thermometrics supplies 4-wire assemblies with matched extension leads.

Standard Lead Wire Options

  • PTFE-insulated, 24 AWG−200 to 260°C
  • Fibreglass-insulated, 24 AWGTo 482°C
  • Ceramic-fiber, 20 AWGTo 980°C
  • Extension grade, PVC jacketStandard industrial

Standard & Custom
Configurations

Immersion / Insertion RTD

Direct-immersion probe for liquid and gas process streams. Straight or tapered immersion length to customer specification. Available with spring-loaded retraction, adjustable compression fittings, or fixed process connections.

  • Fixed or adjustable immersion length
  • Integral or separable connection head
  • Thermowell-compatible tip geometry
  • Weatherproof NEMA 4X heads available

Surface / Weld-Pad RTD

Flat-bottom weld-pad RTDs for tube-skin or pipe-surface measurement. Welded directly to OD surface. Low thermal mass enables fast response to surface temperature changes in heat exchangers and process piping.

  • 316SS or Inconel pad material
  • TIG-weldable base per AWS D17.1
  • Dual-element (measuring + backup) available
  • MIMS lead cable standard

Sanitary / Tri-Clamp RTD

3-A and FDA-compliant assemblies for hygienic process applications. Electropolished wetted surfaces, no crevices, tri-clamp or hygienic thread connections. Full material traceability and surface roughness documentation available.

  • Ra ≤ 0.8 µm electropolished finish
  • 3-A Symbol authorized configurations
  • Spring-loaded tip for vessel wall contact
  • Certificate of Compliance standard

Thermowell-Mounted RTD

RTD element sized to fit standard thermowell bore. Spring-loaded tip ensures consistent thermal contact with the thermowell closed end. Separable design allows element replacement without process shutdown.

  • Compatible with all Thermometrics thermowell bores
  • Spring constant and tip geometry matched to thermowell
  • Quick-disconnect head options
  • Tandem / dual-element available

Why RTDs for
Your Application?

RTDs offer fundamental advantages over thermocouples in accuracy, stability, and linearity — making them the preferred sensor for precision process control, calibration, and laboratory measurement.

01

High Accuracy & Repeatability

IEC 60751 Class A elements achieve ±0.15°C at 0°C. Class AA achieves ±0.1°C. RTDs exhibit excellent long-term drift stability, typically <0.1°C/year in stable environments.

02

Linear Output

RTD resistance-temperature relationship is highly predictable and described by the Callendar-Van Dusen equation, simplifying transmitter linearization and eliminating the need for thermocouple cold-junction compensation.

03

No Reference Junction Required

Unlike thermocouples, RTDs do not require a cold-junction compensation circuit. Two-wire, three-wire, and four-wire configurations allow trade-offs between lead resistance compensation and installation complexity.

04

Wide Material Compatibility

Sheath materials available in 316SS, Inconel 600/625, Hastelloy C276, titanium, and tantalum for aggressive process chemistries. PTFE and ceramic insulation for high-purity and high-temperature applications.

05

NIST-Traceable Calibration

All Thermometrics RTD assemblies are calibrated against NIST-traceable reference standards. Individual calibration certificates with measured R vs. T data are available on request.

06

Custom Lead Lengths & Terminations

Extension leads cut to length, terminated with Amphenol connectors, terminal blocks, or flying leads. Silicone, PTFE, and fibreglass jacket options. Matched resistance extension wire available.

Ready to Specify Your Sensor?

Talk directly to the engineering team that builds your assemblies. No bots, no call centers.